Also known as
Lipoprotein Receptor-related Protein, Low Density
Other names
lipoprotein receptor-related protein; Prolow-density lipoprotein receptor-related protein 1; prolow-density lipoprotein receptor-related protein 1; LRP-1; type V tgf-beta receptor; apolipoprotein E receptor; alpha-2-macroglobulin receptor; TbetaR-V/LRP-1/IGFBP-3 receptor; low density lipoprotein receptor-related protein 1; Alpha-2-macroglobulin receptor; A2MR; Apolipoprotein E receptor
Species reactivity
Human (Homo sapiens); Due to limited knowledge and inability for testing each and every species, the reactivity of the antibody may extend to other species which are not listed hereby.
Specificity and cross-reactivity
Recognizes human CD91.; Since it is not possible to test each and every species our knowledge on the corss reactivity of the antibodies is limited. This particular antibody might cross react with speacies outside of the listed ones.
Purification method
Purified
Form/Appearance
Supplied as a liquid in PBS, pH7.4, 1% BSA, 0.09% sodium azide. Labeled with FITC.
Concentration
N/A
Storage and shipping
Store the antibody at +4 degrees Celsius for short term storage.. For long-term storage and to avoid repeated freezing and thawing, aliquot and For optimal long term storage, the antibody should be kept at -20 degrees Celsius. Aliquots are stable for at least 12 months the antibody should be stored at -20 degrees Celsius.. Prior to use, briefly centrifuge the original vial after thawing and before lid. If further dilution(s) are needed, they can be done with the appropriate assay buffer. FITC conjugates are sensitive to light.
Tested applications:
Flow Cytometry (FC/FACS)
Properties
If you buy Antibodies supplied by MBS Monoclonals they should be stored frozen at - 24°C for long term storage and for short term at + 5°C.This MBS Monoclonals Fluorescein isothiocyanate (FITC) antibody is currently after some BD antibodies the most commonly used fluorescent dye for FACS. When excited at 488 nanometers, FITC has a green emission that's usually collected at 530 nanometers, the FL1 detector of a FACSCalibur or FACScan. FITC has a high quantum yield (efficiency of energy transfer from absorption to emission fluorescence) and approximately half of the absorbed photons are emitted as fluorescent light. For fluorescent microscopy applications, the 1 FITC is seldom used as it photo bleaches rather quickly though in flow cytometry applications, its photo bleaching effects are not observed due to a very brief interaction at the laser intercept. MBS Monoclonals FITC is highly sensitive to pH extremes.