Target's alterntive name
DDIAS, C11orf82, Chromosome 11 Open Reading Frame 82, DNA damage-induced apoptosis suppressor protein
Species Reactivity
Homo sapiens (Human)
Sample Type
Tissue homogenates, Cell lysates and other biological fluids.
Detection Range
0.312-20 ng/mL
Sensitivity
0.114 ng/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nitric Oxide Inducible Gene Protein were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nitric Oxide Inducible Gene Protein were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
Detection Method
Colorimetric
Assay Time
3 hours
Application
For research use only. Not for diagnostic procedures.
Assay Type
Double-antibody Sandwich
Shipping Conditions
Ice packs
Storage Temperature
Short term: 4°C; Long term: see manual.
Precaution of Use
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Shelf life
Use Human Nitric Oxide Inducible Gene Protein (NOXIN) ELISA Kit before 8 months
Specificity
This assay has high sensitivity and excellent specificity for detection of Nitric Oxide Inducible Gene Protein
Cross Activity
No significant cross-reactivity or interference between Nitric Oxide Inducible Gene Protein and analogues was observed.
Test Principle
No significant cross-reactivity or interference between Nitric Oxide Inducible Gene Protein and analogues was observed.
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Quality Systems
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Research Area
Tumor immunity
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED